Computes a calibration factor for converting optical flow sensor units to real-world distance units. The function compares the known physical distance traveled by a trackball (based on its diameter and number of rotations) to the measured distance in sensor units.

Usage

get_trackball_calibration_factor(data, ball_diameter, ball_rotations)

Arguments

data

An aniframe object containing x and y coordinates from the optical flow sensor.

ball_diameter

Numeric. The diameter of the trackball in real-world units (e.g., mm or cm).

ball_rotations

Numeric. The number of complete rotations the ball was rotated during calibration.

Value

A numeric calibration factor (real distance / measured distance). Multiply sensor readings by this factor to convert to real-world units.

Details

The returned calibration factor can be used in set_unit_space.

The function:

  • Calculates the real distance traveled as circumference × rotations

  • Measures the distance in sensor units using the axis with maximum travel

  • Returns the ratio of real distance to measured distance

Examples

if (FALSE) { # \dontrun{
# Calibrate with a 50mm diameter ball rotated 10 times
cal_factor <- get_trackball_calibration_factor(
  data = sensor_data,
  ball_diameter = 50,
  ball_rotations = 10
)
} # }